Maywoflamm® flame retardent plastics are mainly used in the fields of transportation, housing construction, the electrical sector, and the construction industry. Depending on the requirements, there are various fire tests that can be performed in-house at Röchling or at external testing laboratories.
The most widely recognized standard for defining the flammability of plastic materials is the UL 94 rating, a standard issued by Underwriter Laboratories, an independent product safety certification company.
試験法 | 単位 | 数値 | |
---|---|---|---|
密度 | DIN EN ISO 1183-1 | g / cm3 | 1,16 |
燃焼性 | UL 94 | V0 (2mm) |
試験法 | 単位 | 数値 | |
---|---|---|---|
引張降伏応力 | DIN EN ISO 527 | MPa | 19 |
引張破壊呼び歪 | DIN EN ISO 527 | % | 44 |
引張弾性率 | DIN EN ISO 527 | MPa | 2033 |
ノッチ付き衝撃耐性 | DIN EN ISO 179 | kJ / m2 | 8 |
試験法 | 単位 | 数値 | |
---|---|---|---|
融点 | ISO 11357-3 | °C | > 150 °C |
熱伝導率 | DIN 52612-1 | W / (m * K) | 0,17 |
線膨張係数 | DIN 53752 | 10-6 / K | 90 |
ビカットB軟化温度 | DIN EN ISO 306, Vicat B | °C | 87 |
グローワイヤテスト | DIN EN 60695-2 | °C | 825 (0,5mm/ 0,8mm) |
試験法 | 単位 | 数値 | |
---|---|---|---|
表面固有抵抗 | DIN EN 61340 | Ω | > 1012 |
体積固有抵抗 | DIN EN 61340 | Ω | > 1012 |