| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Density | DIN EN ISO 1183-1 | g / cm3 | 1,41 | 
| Water absorption | DIN EN ISO 62 | % | 0,20 | 
| Flammability (Thickness 1 ... 4 mm) | DIN 4102 | B1 | |
| VOC | ISO 16.000 | conform | - | 
| Flammability (Thickness 2,5 mm) | BS 476 Part 6 | Class 0 | |
| Flammability (Thickness 1 ... 4 mm) | NF P 92-501 | M1 | |
| Flammability (Thickness 2 ... 4 mm) | BS 476 Part 7 | Class 1 | |
| Flammability (Thickness 2,5 mm) | EN 13501-1 | B s3 d0 | |
| Flammability (Thickness 4 mm) | EN 13501-1 | B s3 d2 | 
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Yield stress | DIN EN ISO 527 | MPa | 45 | 
| Elongation at break | DIN EN ISO 527 | % | 20 | 
| Tensile modulus of elasticity | DIN EN ISO 527 | MPa | 2500 | 
| Notched impact strength | DIN EN ISO 179 | kJ / m2 | 8 | 
| Shore hardness | DIN EN ISO 868 | scale D | 80 | 
| Ball indentation hardness | DIN EN ISO 2039-1 | MPa | 110 | 
| Compressive strength | DIN EN ISO 604 | MPa | 65 | 
| Bending strength | DIN EN ISO 178 | MPa | 60 | 
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Thermal conductivity | DIN EN ISO 8302 | W / (m * K) | 0,16 | 
| Vicat softening temperature | DIN EN ISO 306, Vicat B | °C | 75 | 
| Service Temperature | °C | -20 ... +60 | |
| Heat deflection temperature | DIN EN ISO 75 | °C | 70 | 
| Coefficient of linear thermal expansion | DIN EN ISO 11359-2 | mm/m K | ∼ 0,075 | 
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Dielectric constant | IEC 60250 | 3,2 | |
| Dielectric dissipation factor (106 Hz) | IEC 60250 | 0,02 | |
| Volume resistivity | DIN EN 62631-3-1 | Ω * cm | >1015 | 
| Surface resistivity | DIN EN 62631-3-2 | Ω | >1013 | 
| Dielectric strength | IEC 60243 | kV / mm | 12 | 
| Comparative tracking index | IEC 60112 | CTI | 600 |