Matrox® is outstanding for its extremely low coefficient of friction and high wear resistance and so optimally meets requirements for the lining of silos and bunkers.
Matrox® SE is a flame-retardant lining material which meets the requirements of the UL 94 V0 fire class.
Test Method | Unit | Guideline Value | |
---|---|---|---|
Hustota | DIN EN ISO 1183-1 | g / cm3 | >0,99 |
Absorpce vody | DIN EN ISO 62 | % | 0,1 |
Hořlavost (tloušťka 3 mm / 6 mm) | UL 94 | V0 | |
Molecular weight | - | 106 g/mol | ∼ 9 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Mez kluzu | DIN EN ISO 527 | MPa | >20 |
Prodloužení při přetržení | DIN EN ISO 527 | % | >50 |
Modul pružnosti v tahu | DIN EN ISO 527 | MPa | >900 |
Vrubová houževnatost | DIN EN ISO 11542-2 | kJ / m2 | >40 |
Tvrdost Shore | DIN EN ISO 868 | scale D | >63 |
Wear resistance | Sand-slurry | 130 | |
Sand Slurry | 1018 Steel=10 | ∼ 90 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Teplota tání | ISO 11357-3 | °C | 130 ... 135 |
Tepelná vodivost | DIN 52612-1 | W / (m * K) | 0,41 |
Thermal capacity | DIN 52612 | kJ / (kg * K) | 1,90 |
Koeficient lineární teplotní roztažnosti | DIN 53752 | 10-6 / K | 150 ... 230 |
Provozní teplota dlouhodobá | Průměr | °C | -200 … 80 |
Provozní teplota krátkodobá (max.) | Průměr | °C | 130 |
Teplota měknutí dle Vicata | DIN EN ISO 306, Vicat B | °C | 79 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Objemový odpor | DIN EN 62631-3-1 | Ω * cm | 109 |
Surface resistivity | DIN EN 62631-3-2 | Ω | 109 |