IT

Scegliere una lingua

 

Durolight® S

GFK-UP

Durolight® is a new developed insulating composite material especially designed to meet the thermal and mechanical requirements of load bearing supports. Durolight® is manufactured from a special formulation of selected synthetic resins in combination with high-strength glass reinforcements.

cream, similar RAL 9001
sheet
QR-Code

Characteristics

  • Low thermal conductivity
  • High mechanical strength
  • Glass-reinforced thermoset SMC high-pressure laminate developed for applications at cryogenic temperatures

Application Examples

Supporti per i sistemi di tubazioni

Durolight® è un materiale isolante fibrorinforzato, sviluppato specificamente per i requisiti termici e meccanici dei supporti per i sistemi di tubazioni. Grazie alla bassa conduttività termica e all’idoneità all’impiego in ambienti con temperature comprese tra -196 °C e +200 °C, Durolight® è adatto per l’isolamento permanente di tubi e come separatore termico nell’industria petrolifera e del gas. Durolight® ha una bassa infiammabilità, è privo di alogeni, resistente agli agenti atmosferici, all’attrito e all’usura. Durlolight è stato approvato da note aziende come Becchtel Corp, Linde AG e Tractebel S.A./N.V.

Variants

Technical Specifications Durolight® S

Test MethodUnitGuideline Value
DensityISO 1183g / cm31,85
Flexural strength 0°CISO 178MPa140
Flexural strength +50°CISO 178MPa125
Flexural strength +100°CISO 178MPa110
Flexural strength +150°CISO 178MPa80
Flexural strength -50°CISO 178MPa160
Flexural strength -100°CISO 178MPa175
Flexural strength -150°CISO 178MPa190 1)
Flexural strength -196°CISO 178MPa205 1)
Modulus of elasticity in flexion 0°CISO 178MPa 9000
Compressive strength 0°CISO 604MPa250
Compressive strength +50°CISO 604MPa220
Compressive strength +100°CISO 604MPa190
Compressive strength +150°CISO 604MPa160
Compressive strength -50°CISO 604MPa280
Compressive strength -100°CISO 604MPa310
Compressive strength -150°CISO 604MPa335 1)
Compressive strength -196°CISO 604MPa360 1)
Tensile strength II 0°CISO 527MPa75
Impact strength (Charpy) RTISO 179kJ / m275
Shear strength II RTDIN EN 60893MPa20
Test MethodUnitGuideline Value
FlammabilityUL 94/V0 / 3mm
Smoke density & toxicity, classNF F 16-101/F0
Fire test, classNF P 92-501/M1
Thermal conductivity RTW / (m * K) 0,3 1)2)
Thermal conductivity -50°CW / (m * K) 0,27 1)2)
Thermal conductivity -196W / (m * K) 0,21 1)2)
Test MethodUnitGuideline Value
Water absorption (4mm thickness)ISO 62%0,2

Contact