| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Density | DIN EN ISO 1183-1 | g / cm3 | 1,45 | 
| Flammability (Thickness 3 mm / 6 mm) | UL 94 | V0 / V0 | 
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Yield stress | DIN EN ISO 527 | MPa | 45 | 
| Elongation at break | DIN EN ISO 527 | % | 15 | 
| Tensile modulus of elasticity | DIN EN ISO 527 | MPa | 3000 | 
| Notched impact strength | DIN EN ISO 179 | kJ / m2 | 2 | 
| Shore hardness | DIN EN ISO 868 | scale D | 79 | 
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Thermal conductivity | DIN 52612-1 | W / (m * K) | 0,2 | 
| Coefficient of linear thermal expansion | DIN 53752 | 10-6 / K | 80 | 
| Service temperature, long term | Average | °C | 0 … 60 | 
| Service temperature, short term (max.) | Average | °C | 70 | 
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Dielectric constant | IEC 60250 | 3 | |
| Dielectric dissipation factor (106 Hz) | IEC 60250 | 0,02 | |
| Volume resistivity | DIN EN 62631-3-1 | Ω * cm | 1015 | 
| Surface resistivity | DIN EN 62631-3-2 | Ω | 1013 |