Characteristics

  • Corrosion resistant
  • Good weldability
  • Good glueability
  • Easy processing
SKUNameTypeTypeColorMeasurementsLengthWidthThicknessHeight
Stock item (no MOQ)
361526Trovidur® EPC white extruded sheet sheet T-182 white3.000 x 1.500 x 5 mm 3,000 mm 1,500 mm 5 mm
Stock item (no MOQ)
361527Trovidur® EPC white extruded sheet sheet T-182 white3.000 x 1.500 x 10 mm 3,000 mm 1,500 mm 10 mm
Stock item (no MOQ)
361911Trovidur® EPC white extruded sheet sheet T-182 white3.000 x 1.500 x 20 mm 3,000 mm 1,500 mm 20 mm
Stock item (no MOQ)
362783Trovidur® EPC white extruded sheet sheet T-182 white3.000 x 1.500 x 4 mm 3,000 mm 1,500 mm 4 mm
Stock item (no MOQ)
362788Trovidur® EPC white extruded sheet sheet T-182 white3.000 x 1.500 x 6 mm 3,000 mm 1,500 mm 6 mm
Stock item (no MOQ)
362789Trovidur® EPC white extruded sheet sheet T-182 white3.000 x 1.500 x 8 mm 3,000 mm 1,500 mm 8 mm
Stock item (no MOQ)
362790Trovidur® EPC white extruded sheet sheet T-182 white3.000 x 1.500 x 15 mm 3,000 mm 1,500 mm 15 mm

Technical Specifications Trovidur® EPC white

Test MethodUnitGuideline Value
DensityDIN EN ISO 1183-1g / cm31,44
Water absorptionDIN EN ISO 62%0,2
Flammability from 4 mmUL 94V0
Flammability (Thickness 4 mm)DIN 4102B1
Test MethodUnitGuideline Value
Yield stressDIN EN ISO 527MPa52
Elongation at breakDIN EN ISO 527%20
Tensile modulus of elasticityDIN EN ISO 527MPa2800
Notched impact strengthDIN EN ISO 179kJ / m24
Shore hardnessDIN EN ISO 868scale D81
Ball HardnessISO 2039MPa110
Compressive strengthDIN EN ISO 604MPa75
Bending strengthDIN EN ISO 178MPa80
Test MethodUnitGuideline Value
Thermal conductivityDIN 52612-1W / (m * K)0,16
Vicat softening temperatureDIN EN ISO 306, Vicat B°C76
Service Temperature°C-15 ... +60
Heat deflection temperatureDIN EN ISO 75°C68
Coefficient of linear thermal expansionDIN EN ISO 11359-2mm/m K 0,075
Glow wire ignition tempeartureDIN EN 60695-2-13°C990
Glow wire flammability indexDIN EN 60695-2-12°C960
Test MethodUnitGuideline Value
Dielectric constantIEC 602503,2
Dielectric dissipation factor (106 Hz)IEC 602500,02
Volume resistivityDIN EN 62631-3-1Ω * cm>1015
Surface resistivityDIN EN 62631-3-2Ω>1013
Dielectric strengthIEC 60243kV / mm12
Comparative tracking indexIEC 60112CTI600

Contact

You have the option of attaching files to your message. The files have to be JPEG, PNG, BMP, PDF-documents. Please be sure that you only add files up to 8 MB

Information on data protection can be found here.

Renew
 
Search

Refine Results

Contact

Share

Newsletter Registration

Select Website

Roechling_Industrial_Banner.jpg
Plastics for technical Applications

Industrial