| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Water Absorption | ASTM D570 | % | 0.01 |
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Hardness | ASTM D2240 | Shore D | 60 |
| Tensile Strength at yield 73°F | ASTM D638 | psi | 2700 |
| Elongation at Break | ASTM D638 | % | >250 |
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| CTE, linear | ASTM D696 | 1/K | 1.0x10-4 |
| Melting Point | °F | 275 | |
| Maximum Service Temperature, Air | °F | 180 | |
| Heat Deflection Temperature 264psi | ASTM D648 | °F | 108 |
| Flammability, UL94 | 1/8 inch | HB |
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Volume Resistivity | ASTM D257 | Ωcm | >1015 |
| Surface resistivity | ASTM D257 | Ω/cm | >1012 |
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| FDA | Yes | ||
| NSF | No | ||
| USDA | Yes |