| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Density | DIN EN ISO 1183-1 | g / cm3 | 1,71 |
| Flammability (Thickness 3 mm / 6 mm) | UL 94 | V0 / V0 |
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Yield stress | DIN EN ISO 527 | MPa | 30 |
| Elongation at break | DIN EN ISO 527 | % | 250 |
| Tensile modulus of elasticity | DIN EN ISO 527 | MPa | 1500 |
| Shore hardness | DIN EN ISO 868 | scale D | 71 |
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Melting temperature | ISO 11357-3 | °C | 230 |
| Thermal conductivity | DIN 52612-1 | W / (m * K) | 0,15 |
| Coefficient of linear thermal expansion | DIN 53752 | 10-6 / K | 90 |
| Service temperature, long term | Average | °C | -50 … 150 |
| Service temperature, short term (max.) | Average | °C | 180 |
| Heat deflection temperature | DIN EN ISO 75, Verf. A, HDT | °C | 70 |
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Volume resistivity | DIN EN 62631-3-1 | Ω * cm | 1015 |
| Surface resistivity | DIN EN 62631-3-2 | Ω | 1013 |
| Comparative tracking index | IEC 60112 | 600 | |
| Dielectric strength | IEC 60243 | kV / mm | 15 |