Test Method | Unit | Guideline Value | |
---|---|---|---|
Density | ASTM D792 | g / cm3 | 1.08 |
Water Absorption | ASTM D570 | % | 0.2 |
Water Absorption 24 hours | ASTM D570 | % | 0.07 |
Dissipation Factor | ASTM D150 | 1MHz | 0.001 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Tensile Strength at Yield | ASTM D638 | psi | 9400 |
Tensile Modulus | ASTM D638 | psi | 350000 |
Tensile Elongation | ASTM D638 | % | 30 |
Flexural Strength | ASTM D790 | psi | 13400 |
Flexural Modulus | ASTM D790 | psi | 360000 |
Rockwell Hardness | ASTM D785 | R | 119 |
Izod Impact, Notched | ASTM D256 | ft-lb/in | 3.5 |
Coefficient of Friction, Dynamic | 0.39 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Thermal Conductivity | in/hr/ft2 /°F | 1.6 | |
Coefficient of Linear Thermal Expansion | ASTM D696 | in/in/°F x10-5 | 3.3 |
Continuous Service Temperature, Air | °F | 220 | |
Deflection Temperature at 1.8Mpa (264psi) | ASTM D648 | °F | 260 |
Deflection Temperature at 1.8Mpa (66psi) | ASTM D648 | °F | 289 |
Flammability, UL94 | 1/8 inch | V-1 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Dielectric constant | ASTM D150 | 1MHz | 2.7 |
Dielectric strength | ASTM D149 | V/mil | 500 |
Surface resistivity | ASTM D257 | Ω/cm | 1017 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
FDA | No | ||
NSF | No |