Test Method | Unit | Guideline Value | |
---|---|---|---|
Density | ASTM D792 | g / cm3 | 1.20 |
Water Absorption 24 hours | ASTM D570 | % | 0.15 |
Dissipation Factor | ASTM D150 | 1MHz | 0.006 |
Water Absorption Saturation | ASTM D570 | % | 0.35 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Hardness | ASTM D2240 | Shore D | 80 |
Tensile Strength at yield 73°F | ASTM D638 | psi | 10000 |
Tensile Modulus | ASTM D638 | psi | 320000 |
Elongation at Break | ASTM D638 | % | 75 |
Flexural Strength | ASTM D790 | psi | 13000 |
Flexural Modulus | ASTM D790 | psi | 340000 |
Rockwell Hardness | ASTM D785 | 75 | |
Rockwell Hardness | ASTM D785 | R | 126 |
Izod Impact, Notched | ASTM D256 | ft-lb/in | 10 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Thermal Conductivity | in/hr/ft2 /°F | 1.3 | |
Coefficient of Linear Thermal Expansion | ASTM D696 | in/in/°F x10-5 | 3.8 |
Melting Point | ASTM D789 | °F | 310 |
Continuous Service Temperature, Air | °F | 250 | |
Deflection Temperature at 1.8Mpa (264psi) | ASTM D648 | °F | 280 |
Deflection Temperature at 1.8Mpa (66psi) | ASTM D648 | °F | 295 |
Flammability, UL94 | 1/8 inch | HB |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Surface resistivity | ASTM D257 | Ω/cm | >1013 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
FDA | ASTM 21EFR177.1582 | Yes | |
NSF | No | ||
USDA | Yes |