Test Method | Unit | Guideline Value | |
---|---|---|---|
Density | ASTM D792 | g / cm3 | 1.04 |
Water Absorption | ASTM D570 | % | 0.7 |
Water Absorption 24 hours | ASTM D570 | % | 0.45 |
Dissipation Factor | ASTM D150 | 1MHz | 0.015 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Tensile Strength at Yield | ASTM D638 | psi | 6100 |
Hardness | ASTM D2240 | Shore D | 74 |
Tensile Modulus | ASTM D638 | psi | 310000 |
Tensile Elongation | ASTM D638 | % | 2000 |
Flexural Strength | ASTM D790 | psi | 10500 |
Flexural Modulus | ASTM D790 | psi | 340000 |
Compressive Strength | ASTM D695 | psi | 7600 |
Rockwell Hardness | ASTM D785 | R | 102 |
Izod Impact, Notched | ASTM D256 | ft-lb/in | 8 |
Coefficient of Friction, Dynamic | 0.35 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Coefficient of Linear Thermal Expansion | ASTM D696 | in/in/°F x10-5 | 5.6 |
Continuous Service Temperature, Air | °F | 170 | |
Deflection Temperature at 1.8Mpa (66psi) | ASTM D648 | °F | 230 |
Flammability, UL94 | 1/8 inch | HB |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Surface resistivity | ASTM D257 | Ω/cm | >1013 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
FDA | No | ||
NSF | No | ||
USDA | No |