Test Method | Unit | Guideline Value | |
---|---|---|---|
Densité | DIN EN ISO 1183-1 | g / cm3 | 1,9 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Flexural strength ┴ | ISO 178 | MPa | 500 |
Flexural strength ┴ +150°C | ISO 178 | MPa | 250 |
Modulus of elasticity in flexion 1)┴ | ISO 178 | MPa | 22500 |
Modulus of elasticity in flexion ┴ +150°C | ISO 178 | MPa | 17000 |
Compressive strength ┴ | ISO 604 | MPa | 500 |
Tensile strength II RT | ISO 527 | MPa | 350 |
Impact strength II (Charpy) | ISO 179 | kJ / m2 | 250 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Thermal conductivity | DIN 52612 | W/m K | 0,35 |
Coefficient of linear expansion ┴ | TMA (Mettler) | 10-6 x K-1 | 40-60 |
Coefficient of linear expansion II | TMA (Mettler) | 10-6 x K-1 | 15-30 |
Temperature index | IEC 60216 | T.I. | 155 |
Insulation class | IEC 60085 | / | F |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Water absorption (method 1) | ISO 62 | % | 0,2 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Electric strength 90°C under oil ┴ | IEC 60243 | kV / mm | 12 |
Electric strength 90°C under oil II | IEC 60243 | kV/25mm | 60 |
Comparative tracking index (test solution A) | IEC 60112 | CTI | 600 |