| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Densité | DIN EN ISO 1183-1 | g / cm3 | 1,64 |
| Water absorption | DIN EN ISO 62 | % | 0,20 |
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Yield stress | DIN EN ISO 527 | MPa | 60 |
| Elongation at break | DIN EN ISO 527 | % | 15 |
| Tensile modulus of elasticity | DIN EN ISO 527 | MPa | 3000 |
| Notched impact strength | DIN EN ISO 179 | kJ / m2 | 6 |
| Shore hardness | DIN EN ISO 868 | scale D | 82 |
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Thermal conductivity | DIN 52612-1 | W / (m * K) | 0,13 |
| Vicat softening temperature | DIN EN ISO 306, Vicat B | °C | 107 |
| Service Temperature | °C | -10 ... +90 | |
| Coefficient of linear thermal expansion | DIN EN ISO 11359-2 | mm/m K | ∼ 0,075 |
| Glow wire ignition tempearture | DIN EN 60695-2-13 | °C | 990 |
| Glow wire flammability index | DIN EN 60695-2-12 | °C | 960 |
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Volume resistivity | DIN EN 62631-3-1 | Ω * cm | >1015 |
| Surface resistivity | DIN EN 62631-3-2 | Ω | >1013 |