Sustason® PSU MG was developed for the high requirements of the healthcare sector for transparent applications such as laboratory equipment, sight glasses or media-carrying components. Compared to PC, the plastic has a 42°C higher glass transition temperature and therefore in the temperature range from 130°C to 160°C a significantly higher strength. It is less sensitivity to stress cracking than PC, too. Furthermore, the amber-coloured transparency is better than that of other amorphous high-performance plastics (PEI, PPSU).
We are a system supplier and partner from the idea to the OEM's end product - as a cooperative value contribution. We are able to support the healthcare industry at the highest level.
Armin Reuner - Industry Manager Healthcare - Mail: AReuner@roechling.com
SKU | Name | Type | Type | Color | Measurements | Length | Width | Thickness | Height | ||
---|---|---|---|---|---|---|---|---|---|---|---|
No stock item (MOQ) | 792987 | Sustason® PSU MG natural extruded | jonc | jonc | naturel | Ø 50 x 3000 mm | 3 000 mm | 50 mm |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Densité | DIN EN ISO 1183-1 | g / cm3 | 1,28 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Yield stress | DIN EN ISO 527 | MPa | 85 |
Elongation at break | DIN EN ISO 527 | % | 7 |
Tensile modulus of elasticity | DIN EN ISO 527 | MPa | 2650 |
Tensile strength | DIN EN ISO 527 | MPa | 85 |
Notched impact strength | ISO 179-1/1eA | kJ / m2 | 2 |
Shore hardness | DIN EN ISO 868 | scale D | 83 |
Ball indentation hardness (H358/30) | DIN EN ISO 2039-1 | MPa | 160 |
Elastic modulus of compression | DIN EN ISO 604 | MPa | 2250 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Température de transistion vitreuse | ISO 11357-3 | °C | 185 |