Test Method | Unit | Guideline Value | |
---|---|---|---|
Densité | DIN EN ISO 1183-1 | g / cm3 | ∼1,40 |
Test Method | Unit | Guideline Value | |
---|---|---|---|
Bending strength | DIN EN ISO 178 | MPa | 80-150 |
Tensile modulus of elasticity | DIN EN ISO 527 | MPa | 5300-7200 |
Tensile modulus of bending | DIN EN ISO 178 | MPa | 5000-8200 |
Notched impact strength | DIN EN ISO 179 | kJ / m2 | 10-14 |
Elongation at break | DIN EN ISO 527 | % | 1,3-3,5 |