Due to its high chemical resistance, polyvinylidene fluoride is often used in chemical apparatus construction. Compared to other fluoroplastics, PVDF offers high mechanical strength and better weldability. Compared to other tank building materials such as PE and PP, its continuous service temperature of 140°C is significantly higher. Its unique UV resistance, high flame retardancy (UL94 V0) and high purity round off its profile. A food grade type (SustaPVDF FG natural) with European food compliance is also available.
| SKU | Name | Type | Type | Color | Measurements | Length | Width | Thickness | Height | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| No stock item (MOQ) | 610755 | SustaPVDF black extruded | rod | rod | black | Ø 70 x 1000 mm | 1 000 mm | 70 mm | |||
| No stock item (MOQ) | 650305 | SustaPVDF black extruded | rod | rod | black | Ø 170 x 2000 mm | 2 000 mm | 170 mm | |||
| No stock item (MOQ) | 650306 | SustaPVDF black extruded | rod | rod | black | Ø 170 x 1000 mm | 1 000 mm | 170 mm | |||
| No stock item (MOQ) | 709077 | SustaPVDF black extruded | rod | rod | black | Ø 170 x 3000 mm | 3 000 mm | 170 mm | |||
| No stock item (MOQ) | 920322 | SustaPVDF black extruded | rod | rod | black | Ø 8 x 3000 mm | 3 000 mm | 8 mm | |||
| No stock item (MOQ) | 927120 | SustaPVDF black extruded | rod | rod | black | Ø 35 x 1000 mm | 1 000 mm | 35 mm | |||
| No stock item (MOQ) | 927399 | SustaPVDF black extruded | rod | rod | black | Ø 25 x 3000 mm | 3 000 mm | 25 mm | |||
| No stock item (MOQ) | 927592 | SustaPVDF black extruded | rod | rod | black | Ø 70 x 3000 mm | 3 000 mm | 70 mm | |||
| No stock item (MOQ) | 929976 | SustaPVDF black extruded | rod | rod | black | Ø 45 x 3000 mm | 3 000 mm | 45 mm |
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Density | DIN EN ISO 1183-1 | g / cm3 | 1,78 |
| Water absorption | DIN EN ISO 62 | % | 0,0 |
| Flammability (Thickness 3 mm / 6 mm) | UL 94 | V0 / V0 |
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Yield stress | DIN EN ISO 527 | MPa | 55 |
| Elongation at break | DIN EN ISO 527 | % | 30 |
| Tensile modulus of elasticity | DIN EN ISO 527 | MPa | 2100 |
| Notched impact strength | DIN EN ISO 179 | kJ / m2 | 12 |
| Shore hardness | DIN EN ISO 868 | scale D | 80 |
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Melting temperature | ISO 11357-3 | °C | 178 |
| Thermal conductivity | DIN 52612-1 | W / (m * K) | 0,2 |
| Thermal capacity | DIN 52612 | kJ / (kg * K) | 1,20 |
| Coefficient of linear thermal expansion | DIN 53752 | 10-6 / K | 140 |
| Service temperature, long term | Average | °C | -20 … 140 |
| Service temperature, short term (max.) | Average | °C | 150 |
| Heat deflection temperature | DIN EN ISO 75, Verf. A, HDT | °C | 115 |
| Test Method | Unit | Guideline Value | |
|---|---|---|---|
| Dielectric constant | IEC 60250 | 9 | |
| Dielectric dissipation factor (50 Hz) | IEC 60250 | 0,02 | |
| Volume resistivity | DIN EN 62631-3-1 | Ω * cm | 1014 |
| Surface resistivity | DIN EN 62631-3-2 | Ω | 1014 |
| Comparative tracking index | IEC 60112 | 600 | |
| Dielectric strength | IEC 60243 | kV / mm | 21 |